Magnet Pull Force Calculator
This calculator estimates the pull force of a disc, cylinder or block magnet. The force acts perpendicular to a thick, flat steel plate. In addition, the tool shows how fast the force drops as an air gap opens up.
Enter Magnet and Steel Contact Details
First, enter the grade or Br of your magnet. Then add its dimensions and any air gap between the magnet and the steel.
Pull Force at Different Air Gaps
Pull force drops quickly once a gap opens between the magnet and the steel. For example, even a thin coating or a sheet of paper matters. The table below applies your current inputs to a series of common gap sizes.
| Air gap (mm) | Pull force (N) | Pull force (kgf) |
|---|
How This Is Calculated
The tool uses the mirror-image method to estimate the force. Then it scales the result with a practical factor, because the ideal model still overstates real-world values.
Step 1: Treat the Steel as a Mirror
First, the tool treats the steel plate as a thick, flat mirror with very high permeability. As a result, the plate pulls on the magnet exactly as a mirror-image magnet would. In other words, the pull force equals the force between the magnet and its image.
Step 2: Add Up the Pole Forces
Next, the tool models the magnet and its image as four uniformly charged pole faces. It adds the attraction and repulsion between every pair of faces. This method includes edge effects and the way the field spreads as the gap grows. Therefore, it follows the real force curve better than the simple formula F = B² A / (2 μ₀).
Reference: G. Akoun and J.-P. Yonnet, "3D analytical calculation of the forces exerted between two cuboidal magnets," IEEE Transactions on Magnetics, vol. 20, no. 5, pp. 1962-1964, 1984.
Step 3: Apply the Practical Factor
However, the ideal model still overstates real pull force. It assumes perfectly flat, thick steel with no coating or air film. Therefore, the tool multiplies the result by a practical factor, 0.85 by default. Set this factor from your own pull-test data for the steel and coating you use.
Steel Thickness
The model assumes steel thick enough to carry the magnet's flux without saturating. However, thin steel saturates, and then the real force drops well below this estimate. For example, a thin sheet gives far less pull than a thick plate.
Sliding Force
The tool estimates sliding (shear) force as 20% of the pull force. This is a common rule of thumb for a magnet on clean, dry steel. However, it does not come from the same field model. It also varies a lot with surface condition.
Engineering Reference
Real pull force also depends on steel thickness, steel grade, surface finish, coating and pull angle. Therefore, treat this result as an engineering estimate, not a guarantee. For force-critical designs, ask our engineers for tested pull-force data. We can match your exact magnet, coating and steel.
Need a magnet rated to a specific pull force?
Share your target force, gap and steel thickness. Then our engineers will recommend the right grade and geometry.