Demagnetization Risk Calculator | King-Nd Magnet

Enter Grade, Temperature and Pc

First, pick a grade and choose the operating temperature. Then enter the permeance coefficient (Pc) of your magnet.

Don't know your Pc? Calculate it from your magnet's shape with the Permeance Coefficient Calculator.

How This Is Calculated

The tool finds the working point where the magnet's load line crosses its demagnetization curve. In fact, circuit designers use the same method to check demagnetization risk.

Step 1: Build the Demagnetization Curve

First, the tool builds the grade's curve at your chosen temperature. It uses the same four-point model as our Demagnetization Curve Tool, so the two tools always agree. These points are Br, HcB, HcJ and the knee field Hk. In addition, we follow the test convention in GB/T 3217 for the magnetic properties of permanent magnet materials.

Step 2: Draw the Load Line

Next, the tool draws the load line from your Pc. The line follows B = Pc × μ₀ × H. In the units used here, this becomes B = Pc × 0.1 × H. H is in kOe, and B is in Tesla. This is the standard link between the permeance coefficient and the operating line.

Step 3: Find the Working Point

Then, the tool finds where the load line crosses the B-H curve. This crossing is the working point (Bd, Hd). As a result, you see both the flux density and the reverse field at that point. The tool locates it by stepping along the tabulated curve.

Step 4: Rate the Risk

Finally, the tool compares the working field Hd with the knee field Hk at that temperature. If Hd is below 80% of Hk, the risk is low. If Hd lies between 80% and 100% of Hk, use caution. If Hd passes Hk, expect partial, irreversible loss of magnetization. Note that the 80% line is an engineering rule of thumb, not a published standard.

What This Model Leaves Out

First, this model assumes a steady, uniform working point. Also, it assumes no extra demagnetizing field, such as a fault current in a motor winding. However, any extra field pushes the working point further along the reverse-field axis. Therefore, treat the margin shown here as the margin under normal operating conditions only.

Engineering Reference

In short, use this tool for early screening only. It does not replace full hysteresis data or FEA simulation. For safety-critical designs, motor fault analysis, or operation near a grade's rated maximum temperature, request full curve data. Our engineers can then review your case directly.