NdFeB Demagnetization Curve Tool | King-Nd Magnet

Select Grades and Temperature

Choose two grades to compare their curves at the same temperature. Alternatively, select the same grade twice. The chart then shows every available temperature for that grade.

VS
Reverse Field -HHover Chart
Flux Density Delta B (B - A)-
Intrinsic Magnetization Delta J (B - A)-
Demagnetization MarginMove mouse over graph
Data status: The tool covers 50SH, 48SH, 52H, 48UH, 48H, 45SH, 40SH, 38UH and 35SH. An asterisk (*) on a temperature button means only one of the two grades has data at that temperature. In that case, the tool plots only that grade. It never fills the gap with the nearest temperature, because that would show a curve that does not exist.

How These Curves Are Built

The curves come from each grade's key specification points. They are not digitized raw test data. Below, we explain how we build them, so you know what the tool can and cannot tell you.

Step 1: Start With Four Datasheet Values

First, each curve starts from four values in the grade's datasheet. These are remanence (Br), normal coercivity (HcB), intrinsic coercivity (HcJ) and knee field (Hk). In addition, we follow the test convention in GB/T 3217, the standard for the magnetic properties of permanent magnet materials.

Step 2: Shape the Intrinsic Curve

Then, between zero field and the knee field Hk, the intrinsic curve J(H) declines slowly and stays close to Br. This flat region is where the magnet is not yet at risk. Beyond Hk, the curve drops more steeply toward HcJ. This drop is the knee, where a grade with lower squareness loses magnetization faster.

Step 3: Derive the Normal Curve

Next, we derive the normal B-H curve from the intrinsic curve with the standard relation B = J − μ₀H. In the units used here, this becomes B = J − 0.1 × H. H is in kOe, and B and J are in Tesla.

What the Tool Cannot Tell You

These curves are smooth models fitted to four key points per grade. As a result, they show the overall shape and the knee position well. However, they miss the small irregularities of a real measured curve. For that level of detail, you need full measured hysteresis loop data.

Symbol Reference

SymbolMeaning
BrRemanence — flux density at H = 0
HcBNormal (B-H) coercivity — field at which B reaches 0
HcJIntrinsic (J-H) coercivity — field at which J reaches 0
HkKnee field — where the J-H curve begins to fall steeply

Engineering Reference

Use these curves for grade selection and early demagnetization-risk screening. However, for FEA simulation or a safety-critical design, request full B-H and J-H data from our engineers. Do not read exact values off this chart.

Evaluating demagnetization risk for your project?

Our interactive tool shows standard curves. However, your application may need full B-H and J-H data for FEA simulation at high temperatures. Contact our team, and we will send you the complete hysteresis data.

Request Full B-H Curve Data →
Want a free sample? Under 1 minuteYour grade is filled in. Just choose a shape and coating, then add your email.
Get My Free Sample →
Scroll to Top