NdFeB Demagnetization Curve Tool
Compare the B-H and J-H demagnetization curves of two sintered NdFeB grades. Each curve covers room temperature up to 180°C. Use the chart to see where a grade starts to lose flux under a reverse field. Then check whether it stays stable at your operating temperature.
Select Grades and Temperature
Choose two grades to compare their curves at the same temperature. Alternatively, select the same grade twice. The chart then shows every available temperature for that grade.
How These Curves Are Built
The curves come from each grade's key specification points. They are not digitized raw test data. Below, we explain how we build them, so you know what the tool can and cannot tell you.
Step 1: Start With Four Datasheet Values
First, each curve starts from four values in the grade's datasheet. These are remanence (Br), normal coercivity (HcB), intrinsic coercivity (HcJ) and knee field (Hk). In addition, we follow the test convention in GB/T 3217, the standard for the magnetic properties of permanent magnet materials.
Step 2: Shape the Intrinsic Curve
Then, between zero field and the knee field Hk, the intrinsic curve J(H) declines slowly and stays close to Br. This flat region is where the magnet is not yet at risk. Beyond Hk, the curve drops more steeply toward HcJ. This drop is the knee, where a grade with lower squareness loses magnetization faster.
Step 3: Derive the Normal Curve
Next, we derive the normal B-H curve from the intrinsic curve with the standard relation B = J − μ₀H. In the units used here, this becomes B = J − 0.1 × H. H is in kOe, and B and J are in Tesla.
What the Tool Cannot Tell You
These curves are smooth models fitted to four key points per grade. As a result, they show the overall shape and the knee position well. However, they miss the small irregularities of a real measured curve. For that level of detail, you need full measured hysteresis loop data.
Symbol Reference
| Symbol | Meaning |
|---|---|
| Br | Remanence — flux density at H = 0 |
| HcB | Normal (B-H) coercivity — field at which B reaches 0 |
| HcJ | Intrinsic (J-H) coercivity — field at which J reaches 0 |
| Hk | Knee field — where the J-H curve begins to fall steeply |
Engineering Reference
Use these curves for grade selection and early demagnetization-risk screening. However, for FEA simulation or a safety-critical design, request full B-H and J-H data from our engineers. Do not read exact values off this chart.
Evaluating demagnetization risk for your project?
Our interactive tool shows standard curves. However, your application may need full B-H and J-H data for FEA simulation at high temperatures. Contact our team, and we will send you the complete hysteresis data.