High-Performance Magnets for AI Data Center Cooling

As AI racks push heat density beyond what air alone can remove, cooling systems run harder, hotter, and around the clock. King-Nd supplies precision magnets for AI data center cooling, powering high-temperature pumps, EC fans, and compressors that keep them running, from direct-to-chip liquid cooling loops to chiller plants.

33 Patents Sintered & Bonded NdFeB ISO 9001 Certified
Data center cooling components showing a magnetic drive pump, axial cooling fan, compressor motor rotor and liquid cooling circulation pump with NdFeB magnets
Outer Magnet Rotor NdFeB segments on the drive side transmit torque through the sealed housing, so the pump needs no shaft seal.
Inner Magnet Rotor Follows the outer rotor and turns the impeller. It sits in the coolant, so coating and encapsulation matter here.
Impeller Driven by the inner rotor to move coolant through the loop. Coupling torque sets the flow it can deliver.
Fan Rotor Magnets A ring of magnet segments inside the external rotor. Uniform magnetization keeps the fan smooth, quiet, and efficient.
Stator Core The windings energize in sequence and push on the rotor magnets. The air gap between the two sets motor efficiency.
Compressor Rotor Magnets Segmented sintered NdFeB around the rotor core. Segmenting helps limit eddy-current heating at high speed.
Retaining Sleeve Holds the magnet segments against centrifugal force at speed, so magnet dimensions must be tightly controlled.
Wet-Rotor Magnet Ring A compact ring magnet fully encapsulated in the coolant path, spinning together with the impeller.
Motor Stator Sits outside the sealed wall and drives the rotor magnet through it, keeping the windings out of the coolant.

Magnet Applications by Cooling System

In a data center cooling system, the magnet sits inside the motor or coupling that moves the coolant and air, so its temperature resistance and consistency show up directly in efficiency and uptime. The tables below outline where King-Nd’s magnet technology fits across liquid cooling, air-side cooling, and chiller plants, along with the magnet forms, processes, and grade families typically specified for each role.

Liquid Cooling Pumps & Coolant Distribution

Component Magnet Form Process Magnetization / Structure Typical Configuration Recommended Grade HRE Free
Magnetic Drive Pump (CDU & loop circulation) Arc Segment / Ring Magnets Sintered NdFeB Radial multi-pole (cylindrical coupling) or axial (disc coupling) 1 outer rotor and 1 inner rotor set per pump, coupled through a sealed housing N42H–N45SH ✔
Cold Plate Loop Pump (wet rotor) Ring / Arc Magnets Sintered or Bonded NdFeB Radial multi-pole 1 rotor magnet per pump, fully encapsulated in the coolant path N38SH–N42SH, or 8–10 MGOe isotropic bonded ✔
Immersion Coolant Circulation Pump Arc Segment / Ring Magnets Sintered NdFeB Radial multi-pole Magnetic coupling that keeps the motor out of the dielectric fluid N42H–N45SH ✔

Fans & Air-Side Cooling

Component Magnet Form Process Magnetization / Structure Typical Configuration Recommended Grade HRE Free
Server & Rack Fan Motor (BLDC rotor) Ring Magnets Bonded NdFeB Multi-pole radial 1 ring per rotor 8–10 MGOe isotropic bonded ✔
CRAH, EC Fan & Rear-Door Fan Motor Arc Segment Magnets Sintered NdFeB Radial, surface-mounted Multiple segments per rotor, bonded to the rotor yoke N38H–N42SH ✔
Fan Speed Sensing Magnet Small Ring / Disc Magnets Bonded NdFeB Multi-pole or diametric 1 per fan, read by a Hall sensor for speed feedback 6–8 MGOe isotropic bonded ✔

Chillers & Heat Rejection

Component Magnet Form Process Magnetization / Structure Typical Configuration Recommended Grade HRE Free
High-Speed Compressor Motor Rotor (oil-free chillers) Segmented Block / Arc Magnets Sintered NdFeB Parallel or radial, sleeve-retained Multiple segments per rotor, held in place by a retaining sleeve N38SH–N42SH, UH series for hotter rotors ✔
Dry Cooler & Cooling Tower Fan Motor Arc Segment Magnets Sintered NdFeB Radial, surface-mounted Multiple segments per rotor, bonded to the rotor yoke N38H–N42SH ✔

Engineered for Heat, Fluids, and 24/7 Operation

Cooling systems cannot afford to stop. King-Nd addresses the demands of continuous operation through high-temperature grade selection, controlled magnet geometry, and coating options matched to the coolant.

Challenge 01

Heat Without Demagnetization

Warm coolant plus motor self-heating push magnets close to their temperature limit. Irreversible flux loss reduces pump torque and fan efficiency and can end in a stalled rotor.

King-Nd Solution

High-coercivity H, SH, and UH grades selected with margin above the real rotor temperature, with consistent output from lot to lot.

Challenge 02

Efficiency and Eddy-Current Loss

In high-speed rotors and magnetic couplings, eddy currents inside the magnets turn into heat and waste energy, which matters when cooling itself consumes a large share of a data center's power.

King-Nd Solution

Segmented sintered designs for high-speed rotors, and resin-insulated bonded rings where low eddy-current loss and net-shape forming are the priority.

Challenge 03

Coolant Compatibility and a Clean Loop

Glycol-water and dielectric fluids can attack unprotected magnets, and any coating particle that enters the loop can clog microchannel cold plates.

King-Nd Solution

Corrosion-resistant coating options matched to the fluid, with full-encapsulation assembly for magnets that sit in the coolant path.

Challenge 04

Balance and Precision at Speed

Fans and compressor rotors run continuously at high speed, where uneven magnetization or poor concentricity turns into vibration, noise, and bearing wear.

King-Nd Solution

Tight dimensional tolerances and magnetization uniformity, with traceable production so every batch behaves like the last one.

Product Capabilities for Data Center Cooling

From high-temperature sintered segments to precision bonded rings and ready-to-integrate rotor and coupling assemblies, King-Nd supplies the magnet products that cooling system designers rely on. Explore our core product lines below.

Sintered NdFeB Magnets

High-temperature arc segments, blocks, and rings for magnetic drive pumps, EC fan motors, and compressor rotors, where strong, stable torque at elevated temperature is the priority.

View Grade Chart

Bonded NdFeB Magnets

Net-shape multi-pole rings for server fans, small wet-rotor pumps, and speed sensing. The resin matrix keeps eddy-current loss low and allows complex shapes in a single piece.

Supplied in both sintered and bonded NdFeB, matched to the demands of each component.

View Bonded NdFeB

Magnetic Assemblies

Rotor assemblies and magnetic coupling sets for pumps and fans, engineered ready to integrate directly into your cooling product.

View Assemblies

Certified Quality, Proven Reliability

Data center operators measure cooling equipment in uptime, which means magnet suppliers need to back up performance claims with process discipline. King-Nd’s certifications and patent portfolio reflect a sustained investment in both manufacturing consistency and materials science.

ISO 9001

Certified quality management system ensuring consistent process control and product quality across every production batch.

ISO 14001

Certified environmental management system supporting responsible, sustainable manufacturing practices.

ISO 45001

Certified occupational health and safety management system, reflecting our commitment to a safe manufacturing environment.

33 Patents

A quantifiable measure of our sustained investment in magnetic materials science and product innovation.

Where Our Magnets Are Already at Work

From hyperscale AI campuses to colocation halls and edge sites, King-Nd’s magnet technology supports the cooling equipment that keeps compute online.

Hyperscale & AI Data Centers
Direct-to-Chip Liquid Cooling
Immersion Cooling Systems
CRAH, CRAC & Rear-Door Cooling
Chiller Plants & Heat Rejection

Ready to Discuss Your Cooling Application?

Whether you're designing a magnetic drive pump, an EC fan motor, or a compressor rotor, our engineering team can help you select the right magnet grade, magnetization, and geometry for your operating temperature and fluid.

Contact Our Engineering Team